Combustion Air Systems
CAS-1 and CAS-2 (Oil)
Direct Connect
The CAS-1 and CAS-2 Field Combustion Air Systems provide controlled amounts of outside air for proper combustion of oil heating appliances. These models are designed specifically for use with Aero, Beckett, Carlin, Riello, or Wayne burners.
|
|
 |
| When to use the CAS |
• Too tight construction.
• Provide source of fresh air for combustion.
• CAS-1 and CAS-2 connect directly to oil burners.
• CAS-3, CAS-4, CAS-6 and CAS-7 are for multiple appliances or when direct connection is not possible. |
|
| Longer intake air runs require the use of larger diameter pipe between the VRV and the intake air hood. Use a pipe increaser at the VRV and a reducer at the intake air hood. |
AirBoot® / FurnaceBoot™ |
Pipe Diameter |
Maximum Linear Feet |
Feet/Elbow |
|
4" |
44' |
7' |
|
5" |
60' |
9' |
|
6" |
90' |
11' |
Field BigBoot® |
6" |
30' |
11' |
|
7" |
60' |
12' |
|
8" |
100' |
14' |
| Model |
Fuel |
Burner |
Appliance Input |
Components |
| CAS-1 |
Oil |
Beckett AFII, NX, Riello 40BF |
Up to 2 gph |
4" Intake Air Hood
4" Vacuum Relief Valve |
CAS-2B
CAS-2C
CAS-2W |
Oil |
Beckett AFG or AF, Carlin EZ-1, CRD, FRD, Wayne MSR |
Up to 2 gph |
4" Intake Air Hood
4" Vacuum Relief Valve
Field AirBoot® |
| CAS-2B-90E |
Oil |
Beckett AF and AFG, warm air furnaces |
Up to 1.5 gph |
4" Intake Air Hood
4" Vacuum Relief Valve
FurnaceBoot™ |
| CAS-2BB |
Oil |
Beckett SF, SMG, CF-500, CF-800 |
Up to 4.5 gph |
6" Intake Air Hood
6" Vacuum Relief Valve
Field BigBoot® |
| CAS-2B375 |
Oil |
Beckett CF-375 and AFG |
Up to 3.5 gph |
6" Intake Air Hood
6" Vacuum Relief Valve
Field BigBoot® |
| CAS-2CB |
Oil |
Carlin, 99-FRD, 100-CRD, 102-CRD, EZ-3 |
Up to 4.5 gph |
6" Intake Air Hood
6" Vacuum Relief Valve
Field BigBoot® |
|